Model MP-710

The MP-710 centrifugal fan is manufactured entirely in polypropylene, specifically designed to provide corrosion resistance in demanding industrial environments.

Following our technical nomenclature, this model features an inlet and outlet diameter of 710 mm, facilitating integration into your extraction system. Custom made-to-order with a direct drive design, the MP-710 ensures maximum mechanical efficiency for flow rates up to 40,000 m³/h. Additionally, it is available with different power ratings and rotation speeds, with a maximum pressure of 275 mmH₂O.

How can we help you?

Max Flow Rate: 40,000 m³/h
Min Flow Rate: 13,500 m³/h
Max Pressure: 232 mmwc
Motor Power: 30.0 kW
Speed (RPM): 1,000
Sound Pressure Level: 88 dB
Weight: 750 Kg
Max Intensity 400v: 56.5 A
*With free outlet at 1.5m.
Max Flow Rate: 40,000 m³/h
Min Flow Rate: 23,000 m³/h
Max Pressure: 275 mmwc
Motor Power: 45.0 kW
Speed (RPM): 1,500
Sound Pressure Level: 93 dB
Weight: 650 Kg
Max Intensity 400v: 83.9 A
*With free outlet at 1.5m.
Fan Chart MP-710 - Performance Curves

Performance Curves: MP-710

Pressure conversion
=
AirFlow conversion
=
*Lines show performance at 50Hz, 45Hz and 40Hz.
*Tests performed according to ISO 5801 standard.

Chemical resistance check

Do you need to verify the compatibility of a specific compound with our materials?


VIEW CHEMICAL RESISTANCE CHART

FAN DIMENSIONS

Dimensions Table MP-710 Series Fans
Model Unit ABCDEFGHIJKL
MP-710 30kW 1000rpm mm 4258458087102054197811138757936407401652.0
Inch 16.733.331.828.080.977.943.834.431.225.229.165.0
MP-710 45kW 1500rpm mm 457600701710172915408418807544707011528.0
Inch 18.023.627.628.068.160.633.134.629.718.527.660.2

Energy Efficiency: High-efficiency IE3 motors.

ATEX Version: Available in PP-EL-s (electro-conductive) version for Zones 1 and 2, strictly complying with the 2014/34/EU directive.

Available with motors for different voltages and frequencies, ensuring compatibility for projects anywhere in the world. Recommended operating temperature range from -10ºC to +85ºC.

IE3 efficiency motors. *The ECODESIGN Directive 2009/125/EC does not apply to the Corrosion-resistant fan range. It is recommended that MP range fans be controlled by a frequency drive.

ATEX Fan Impeller PP-EL-s

Do you need the CAD drawing or a specific curve for your project?

At Quimipol, we validate your duty point. Contact our technical office to receive the necessary advice and ensure that the MP-710 is the best option for your installation.